
Indonesia Energy & Engineering Virtual Expo (IEE VEXPO) 2021
Indonesia Energy & Engineering Virtual Expo 2021 (IEE VEXPO) was a business to business (B2B) virtual exhibition covering 5 major sectors, with Energy represents electric & power, mining, and oil & gas sectors and Engineering represents construction, concrete and building technology sectors. The virtual show combines 4-day online exhibition, business matching programme, and daily live webinar series with specific sector highlights.
The virtual exhibition allowed our visitors to learn our brand identity as well as our products. E-catalogues and live consultation was provided in order the visitors to know in depth regarding our business. 4 day of virtual exhibition brought us to 300++ booth visitors and more than 10 booking for consultation.
Download Brochure
Please download following of our brochure to meet your requirements:
- LV Switchgear & Control gear IEC 61439
- Degree of Protection IEC 529
- Internal Aro Fault IEC 61641
- Resistance to Salt mist IEC 60068-2-11
- Resistance to Damp heat IEC 60068-2-30

Standard and Regulation
Standard IEC 61643-1 (Surge Protecting)
Protector Parameter
• Level of Protection (Up)
Maximum residual voltage between the terminals of the protection device during the application of the peak current.
• Nominal Current (In)
Peak current in 8/20 µs waveform the protection device can withstand 20 times without reaching end of life.
• Maximum Discharge Current (Imax)
Peak current with 8/20 µs waveform in single pulse which the protection device can withstand without reaching end of life. This parameter is used in Class II SPD
• Maximum Continuous Operating Voltage (Uc)
Maximum effective voltage (r.m.s or dc) that can be applied permanently to the terminals of the protection device
• Impulse Current (Iimp)
Peak current with 10/350 µs waveform which the protection device can withstand without reaching end of life. This parameter is used in Class I SPD
Classification of protectors
• Class I
Tested with a 10/350 µs waveform, simulates the current produced by a direct lightning strike.
High Protection Level (Up). Class I protector are required where a direct impact of lightning are expected or there is a lightning protection system. These protectors must be installed at the main incomer due its high discharge capacity and the main incomer expects the highest exposure to overvoltage. Must be accompanied by downstream Class II protector.
• Class II
Tested with a 8/20 µs waveform, simulates the current produced in the event of a switching or lightning strike on the distribution line or its vicinity.
Medium Protection Level (Up). Class II protector is required in the downstream of Class I SPD at the main incomer where there is not external protection or the distance from installation with an external protection is less than 50 m, or in areas with low exposure to lightning strikes.
• Class III
Tested with a combined 1.2/50 µs - 8/20 µs waveform, simulates the current and voltage that can reach the equipment to be protected.
Low Protection Level (Up). Must be installed to protect sensitive equipment for individuals and industrial equipments, and on equipments over 20 m away from where the Class II SPD is installed.
* The technology can provide protection solutions that combine different types of protection: Class I+II and Class II+III.

Parameter
• Description:
“Power frequency overvoltage protective devices for household and similar applications (POP)” published on March 16, 2011, is the first standard for power frequency overvoltage protection.
• Objective:
To mitigate the effects of power frequency over voltages between phase and neutral conductor caused by breakage of neutral.
• Scope of the standard:
Power frequency overvoltage protectors (POP) for household and similar applications.
Salient Point
• Progressive Voltage/Time tripping curve.
The tripping time depends on the magnitude of the overvoltage, ensuring quick tripping in the case of severe disturbances while avoiding unwanted activation in the event of small voltage increases.
• Common Manufacturer
Common manufacturer of the power frequency overvoltage protector and the MCB.
• Prohibition on using earth leakage or current differential as operating principles.



Company Overview
Established in 2013, Puma Elektrik Niaga (PEN) operates as a specialized business unit focusing on the marketing and sales of Medium Voltage (MV) and Low Voltage (LV) switchboard components and accessories. Our primary markets include panel builders, electrical distributors, and suppliers across Indonesia.
![]()
Our Solution



Electrical & Power Indonesia (EPRE) 2023
ASEAN’s largest Electric & Power exhibition takes place in South East Asia’s most dynamic market Indonesia is Electrical & Power 2023 exhibition. Puma Elektrik Niaga comes to participating this exhibiton that was held at Jiexpo Kemayoran from 13 to 16 September 2023.
This event provides 3-cross functional of network, business opportunities, and brand identity. Technology in this era encourage us to keep relevant and we proudly present displaying PEN’s new products that comes for fill your needs. Also we want to support of nationally government regulation about component level, so we presents our sample of local products. These are such as our strategy to build a new business opportunities
Last, we would like to say thankyou to our visitors who were mostly electrical segmentation companies for kept coming to the PEN booth because of their interest about our products and discuss with the PEN sales and marketing team. We look forward to establishing a long and fruitful relationship with you.
HBBL 2022
|
Hannover Messe 2021 |
|
|
Hari Belanja Barang Lokal 2022 was held in May 2022 and participated by more than 1000 local brands. The purpose of this event was to provide platform for the local brands especially those who just started to create brand awareness as well as to introduce their product quality. Puma Elektrik Niaga introduced 4 main products in HBBL 2022 such as Cable Duct, Cable Schoen, Current Transformer and Terminal Block. Those are our best seller products and are made locally by PM with premium quality. |
Hannover Messe is one of biggest exhibition of technology industry in the world. This event was a big chance for Indonesia to Indonesian’s electrical products to the world and to transform economy especially in 4.0 industry as well as the national economy during pandemic Covid 19. This event is a platform to introduce technological development in Indonesia, and to encourage bilateral industry connection and collaboration between Indonesia with Germany. The companies who participated on this event are company industry in big scale, middle industry, and small until start up. More than 150 participant also participated to showing off their excellence products. |
|
Fungsi Kapasitor Bank dan Manfaatnya untuk Efisiensi Listrik |
Fungsi Current Transformer (CT) di Dalam Panel Listrik |
|
|
Kapasitor bank memiliki peranan penting dalam sistem kelistrikan, terutama pada instalasi industri dan bangunan komersial. Fungsi utama kapasitor bank adalah sebagai penyeimbang muatan induktif agar sistem kelistrikan bekerja lebih efisien dan stabil.
|
Apa Itu Current Transformer (CT)? Current Transformer (CT) atau Trafo Arus adalah komponen penting dalam panel listrik yang berfungsi untuk mengukur arus listrik bertegangan tinggi secara aman. CT bekerja dengan cara menurunkan arus besar pada jaringan listrik menjadi arus yang lebih kecil dan aman agar bisa dibaca oleh alat ukur seperti ammeter, wattmeter, atau sistem monitoring energi (SCADA) tanpa merusak peralatan tersebut.
|
|




